APPLICATION EXAMPLE

Emergency equipment lighting with EMERALD-FS & -ER1


For help with an application simulation using our optics, or to make a request about what application you want us to cover next, contact Tech support

SETUP:

Application:Emergency lighting
LED:HP 3535
Installation height:3 m
Luminaire info (1 & 3)
Optics:EMERALD-FS
Number of luminaires:2 pcs (One for each equipment)
Spacing:7.9 m
Lumen output:133 lm
Power:1 W
Luminaire info (2)
Optics:EMERALD-ER1
Number of luminaires:3 pcs (Along the hallway)
Spacing:11 m
Lumen output:69 lm
Power:0.5 W

RESULTS:

Results are calculated ignoring objects.
Calculation surface 1
Average:5.6 lx
Min:1.9 lx
Max:13.2 lx
Calculation surface 2
Average:5.6 lx
Min:1.4 lx
Max:13.2 lx
Floor
Average:4.3 lx
Min:1.5 lx
Max:19.1 lx

Download and edit the dialux file

Fill the form to receive download link to your inbox
By giving your contact details you agree to your data being processed by LEDiL in accordance with applicable personal data legislation and LEDiL privacy policy.



Emergency equipment lighting with EMERALD-FS & -ER1


For help with an application simulation using our optics, or to make a request about what application you want us to cover next, contact Tech support

The information contained herein is the property of LEDiL Oy, Joensuunkatu 13, FI-24100 SALO, Finland and is subject to change without notice. Please visit www.ledil.com for additional information, such as the latest photometric files, 3D mechanical models, and application notes relating to handling, gluing and taping.

Copyright © 2018-2021 LEDiL. All rights reserved.

We place great importance in protecting our intellectual property rights and our products with patents, trademarks, design rights or other intellectual property rights, which we defend through active enforcement.