APPLICATION EXAMPLE
Emergency equipment lighting with EMERALD-FS & -ER1
For help with an application simulation using our optics, or to make a request about what application you want us to cover next, contact Tech support
SETUP:
Application: | Emergency lighting |
LED: | HP 3535 |
Installation height: | 3 m |
Luminaire info (1 & 3) | |
Optics: | EMERALD-FS |
Number of luminaires: | 2 pcs (One for each equipment) |
Spacing: | 7.9 m |
Lumen output: | 133 lm |
Power: | 1 W |
Luminaire info (2) | |
Optics: | EMERALD-ER1 |
Number of luminaires: | 3 pcs (Along the hallway) |
Spacing: | 11 m |
Lumen output: | 69 lm |
Power: | 0.5 W |
RESULTS:
Results are calculated ignoring objects. | |
Calculation surface 1 | |
Average: | 5.6 lx |
Min: | 1.9 lx |
Max: | 13.2 lx |
Calculation surface 2 | |
Average: | 5.6 lx |
Min: | 1.4 lx |
Max: | 13.2 lx |
Floor | |
Average: | 4.3 lx |
Min: | 1.5 lx |
Max: | 19.1 lx |
C18138_EMERALD-FS-PC | ||
CA18139_EMERALD-FS-PC | Variant with installation tape. | |
C17718_EMERALD-ER1-PC | ||
CA17721_EMERALD-ER1-PC | Variant with installation tape. |
Emergency equipment lighting with EMERALD-FS & -ER1
For help with an application simulation using our optics, or to make a request about what application you want us to cover next, contact Tech support
The information contained herein is the property of LEDiL Oy, Joensuunkatu 7, FI-24100 SALO, Finland and is subject to change without notice. Please visit www.ledil.com for additional information, such as the latest photometric files, 3D mechanical models, and application notes relating to handling, gluing and taping.